Fix: SPH Batterie-Leistung aus Energiebilanz statt Register 1009/1011 (v1.7.5)
Register 1009 (bat_discharge) liefert beim SPH im Lademodus falsche Werte. Neue Ableitung: bat_net = pv1+pv2 + power_to_user - power_to_grid - ac_power_total Alle vier Quellen sind direkt gemessene, verlässliche Register. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
name: ShineBridge
|
||||
version: "1.7.4"
|
||||
version: "1.7.5"
|
||||
slug: shinebridge
|
||||
description: Growatt Wechselrichter lokal in Home Assistant — Modbus TCP via ShineLAN-X, MQTT Discovery, Web UI
|
||||
url: https://gitea.bitfire.work/retr0/shinebridge
|
||||
|
||||
+11
-4
@@ -245,12 +245,19 @@ def _poll_loop(inv_cfg: Dict[str, Any], stop: threading.Event):
|
||||
if values and "grid_power" not in values and "import_kwh" in values and "total_power" in values:
|
||||
values["grid_power"] = values["total_power"]
|
||||
|
||||
# Growatt SPH: beide Batterie-Register können gleichzeitig != 0 sein (Messartefakt).
|
||||
# Batterie kann physikalisch nur laden ODER entladen — kleineren Wert auf 0 setzen.
|
||||
if values and "bat_charge_power" in values and "bat_discharge_power" in values:
|
||||
if values["bat_charge_power"] >= values["bat_discharge_power"]:
|
||||
# Growatt SPH: Register 1009/1011 für Batterie sind unzuverlässig (Messartefakt).
|
||||
# Batterie-Nettoleistung wird stattdessen aus der Energiebilanz abgeleitet:
|
||||
# bat_net = PV + grid_import - grid_export - ac_power_total
|
||||
# Alle vier Quellen sind direkt gemessene, verlässliche Register.
|
||||
if values and all(k in values for k in ("pv1_power", "ac_power_total",
|
||||
"power_to_user", "power_to_grid")):
|
||||
pv = values.get("pv1_power", 0) + values.get("pv2_power", 0)
|
||||
bat_net = pv + values["power_to_user"] - values["power_to_grid"] - values["ac_power_total"]
|
||||
if bat_net >= 0:
|
||||
values["bat_charge_power"] = round(bat_net, 1)
|
||||
values["bat_discharge_power"] = 0.0
|
||||
else:
|
||||
values["bat_discharge_power"] = round(-bat_net, 1)
|
||||
values["bat_charge_power"] = 0.0
|
||||
|
||||