@@ -0,0 +1,183 @@
esphome:
name: growatt-mic-1500
friendly_name: Growatt MIC 1500 TL-X
esp8266:
board: esp07s
logger:
api:
encryption:
key: "HIER_API_KEY_EINTRAGEN" # 32-Byte Base64-Key, wird in der ESPHome-UI automatisch generiert
ota:
- platform: esphome
password: "HIER_OTA_PASSWORT_EINTRAGEN" # Beliebiges Passwort für Over-the-Air Updates
wifi:
ssid: "HIER_WLAN_NAME_EINTRAGEN" # Name deines WLANs (SSID)
password: "HIER_WLAN_PASSWORT_EINTRAGEN" # Passwort deines WLANs
ap:
ssid: "Growatt MIC 1500 TL-X Fallback Hotspot"
password: "HIER_HOTSPOT_PASSWORT_EINTRAGEN" # Passwort für den Notfall-Hotspot (min. 8 Zeichen)
captive_portal:
time:
- platform: homeassistant
id: homeassistant_time
output:
# Blue Led
- id: light_bl
platform: gpio
pin: 16
# Green Led
- id: light_gr
platform: gpio
pin: 0
# Red Led
- id: light_rd
platform: gpio
pin: 2
uart:
id: mod_bus
tx_pin: 1
rx_pin: 3
baud_rate: 115200
modbus:
id: modbus1
uart_id: mod_bus
modbus_controller:
- id: growatt
# the Modbus device addr
address: 0x1
modbus_id: modbus1
setup_priority: -10
sensor:
- platform: modbus_controller
name: "DcPower"
address: 5
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:flash
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "DcVoltage"
address: 3
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "DcInputCurrent"
address: 4
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "AcFrequency"
address: 37
register_type: "read"
unit_of_measurement: Hz
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.01
- platform: modbus_controller
name: "AcVoltage"
address: 38
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "AcOutputCurrent"
address: 39
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "AcPower"
address: 40
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:flash
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "EnergyToday"
address: 53
register_type: "read"
unit_of_measurement: kWh
device_class: energy
icon: mdi:flash
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "EnergyTotal"
address: 55
register_type: "read"
unit_of_measurement: kWh
state_class: total_increasing
device_class: energy
icon: mdi:flash
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Temperature"
address: 93
register_type: "read"
unit_of_measurement: C
device_class: temperature
icon: mdi:thermometer
value_type: U_WORD
accuracy_decimals: 1
filters: