Initiale Konfiguration

ESPHome-Configs für Growatt MIC 1500 TL-X und SPH 5000 TL3-BH-UP
mit Modbus-RTU Integration über den Growatt SuniStick.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
2026-04-07 21:30:04 +02:00
commit cc67e9843c
4 changed files with 822 additions and 0 deletions
@@ -0,0 +1,387 @@
esphome:
name: growatt-sph5000
friendly_name: Growatt SPH 5000 TL3-BH-UP
esp8266:
board: esp07s
logger:
api:
encryption:
key: "HIER_API_KEY_EINTRAGEN" # 32-Byte Base64-Key, wird in der ESPHome-UI automatisch generiert
ota:
- platform: esphome
password: "HIER_OTA_PASSWORT_EINTRAGEN" # Beliebiges Passwort für Over-the-Air Updates
wifi:
ssid: "HIER_WLAN_NAME_EINTRAGEN" # Name deines WLANs (SSID)
password: "HIER_WLAN_PASSWORT_EINTRAGEN" # Passwort deines WLANs
ap:
ssid: "Growatt-SPH5000 Fallback Hotspot"
password: "HIER_HOTSPOT_PASSWORT_EINTRAGEN" # Passwort für den Notfall-Hotspot (min. 8 Zeichen)
captive_portal:
time:
- platform: homeassistant
id: homeassistant_time
output:
- id: light_bl
platform: gpio
pin: 16
- id: light_gr
platform: gpio
pin: 0
- id: light_rd
platform: gpio
pin: 2
uart:
id: mod_bus
tx_pin: 1
rx_pin: 3
baud_rate: 115200
modbus:
id: modbus1
uart_id: mod_bus
modbus_controller:
- id: growatt
address: 1
modbus_id: modbus1
setup_priority: -10
sensor:
# --- PV Eingang ---
- platform: modbus_controller
name: "PV1 Voltage"
address: 3
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:solar-panel
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "PV1 Current"
address: 4
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:solar-panel
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "PV1 Power"
address: 5
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:solar-panel
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "PV2 Voltage"
address: 7
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:solar-panel
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "PV2 Current"
address: 8
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:solar-panel
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "PV2 Power"
address: 9
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:solar-panel
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- AC Ausgang / Netz ---
- platform: modbus_controller
name: "AC Output Power Total"
address: 35
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:flash
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Frequency"
address: 37
register_type: "read"
unit_of_measurement: Hz
device_class: frequency
icon: mdi:sine-wave
value_type: U_WORD
accuracy_decimals: 2
filters:
- multiply: 0.01
- platform: modbus_controller
name: "Grid Voltage L1"
address: 38
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Current L1"
address: 39
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Voltage L2"
address: 42
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Current L2"
address: 43
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Voltage L3"
address: 46
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Grid Current L3"
address: 47
register_type: "read"
unit_of_measurement: A
device_class: current
icon: mdi:flash
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- Energie (PV Erzeugung) ---
- platform: modbus_controller
name: "Energy Today"
address: 53
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:solar-power
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Energy Total"
address: 55
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:solar-power
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- Temperatur ---
- platform: modbus_controller
name: "Inverter Temperature"
address: 93
register_type: "read"
unit_of_measurement: "°C"
device_class: temperature
icon: mdi:thermometer
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- Batterie ---
- platform: modbus_controller
name: "Battery Discharge Power"
address: 1009
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:battery-minus
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Battery Charge Power"
address: 1011
register_type: "read"
unit_of_measurement: W
device_class: power
icon: mdi:battery-plus
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Battery Voltage"
address: 1013
register_type: "read"
unit_of_measurement: V
device_class: voltage
icon: mdi:battery
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Battery State of Charge"
address: 1014
register_type: "read"
unit_of_measurement: "%"
device_class: battery
icon: mdi:battery
value_type: U_WORD
accuracy_decimals: 0
- platform: modbus_controller
name: "Battery Temperature"
address: 1040
register_type: "read"
unit_of_measurement: "°C"
device_class: temperature
icon: mdi:thermometer
value_type: U_WORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- Batterie Energie (kWh Zähler für Energie-Dashboard) ---
- platform: modbus_controller
name: "Battery Discharge Total"
address: 1054
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:battery-minus
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Battery Charge Total"
address: 1058
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:battery-plus
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
# --- Netzenergie Import / Export (kWh Zähler für Energie-Dashboard) ---
- platform: modbus_controller
name: "Energy Import Total"
address: 1046
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:transmission-tower-import
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
- platform: modbus_controller
name: "Energy Export Total"
address: 1050
register_type: "read"
unit_of_measurement: kWh
device_class: energy
state_class: total_increasing
icon: mdi:transmission-tower-export
value_type: U_DWORD
accuracy_decimals: 1
filters:
- multiply: 0.1
+83
View File
@@ -0,0 +1,83 @@
# Growatt SPH 5000 TL3-BH-UP — ESPHome Konfiguration
Modbus-RTU Integration des Growatt SPH 5000 TL3-BH-UP (3-phasiger Hybrid-Wechselrichter mit Batterie) über einen Growatt SuniStick mit ESPHome-Firmware.
---
## Modbus-Register Übersicht
Alle Register sind **Input Register** (Modbus Funktionscode 04, `register_type: "read"`).
Modbus-Adresse des Geräts: `0x01`
### PV Eingang
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| PV1 Voltage | 3 | U_WORD | 0.1 | V |
| PV1 Current | 4 | U_WORD | 0.1 | A |
| PV1 Power | 5 | U_DWORD | 0.1 | W |
| PV2 Voltage | 7 | U_WORD | 0.1 | V |
| PV2 Current | 8 | U_WORD | 0.1 | A |
| PV2 Power | 9 | U_DWORD | 0.1 | W |
### AC Ausgang / Netz
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| AC Output Power Total | 35 | U_DWORD | 0.1 | W |
| Grid Frequency | 37 | U_WORD | **0.01** | Hz |
| Grid Voltage L1 | 38 | U_WORD | 0.1 | V |
| Grid Current L1 | 39 | U_WORD | 0.1 | A |
| Grid Voltage L2 | 42 | U_WORD | 0.1 | V |
| Grid Current L2 | 43 | U_WORD | 0.1 | A |
| Grid Voltage L3 | 46 | U_WORD | 0.1 | V |
| Grid Current L3 | 47 | U_WORD | 0.1 | A |
> **Wichtig:** Grid Frequency hat Multiplikator `0.01` — der Rohwert ist z.B. `5000` = 50,00 Hz.
### Energie (PV Erzeugung)
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| Energy Today | 53 | U_DWORD | 0.1 | kWh |
| Energy Total | 55 | U_DWORD | 0.1 | kWh |
### Temperatur
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| Inverter Temperature | 93 | U_WORD | 0.1 | °C |
### Batterie — Momentanleistung
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| Battery Discharge Power | 1009 | U_DWORD | 0.1 | W |
| Battery Charge Power | 1011 | U_DWORD | 0.1 | W |
| Battery Voltage | 1013 | U_WORD | 0.1 | V |
| Battery State of Charge | 1014 | U_WORD | 1 | % |
| Battery Temperature | 1040 | U_WORD | 0.1 | °C |
### Batterie — Energie (für Energie-Dashboard)
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| Battery Discharge Total | 1054 | U_DWORD | 0.1 | kWh |
| Battery Charge Total | 1058 | U_DWORD | 0.1 | kWh |
> **Wichtig:** 1009/1011 = Momentanleistung in **Watt**. 1054/1058 = kumulierte Energie in **kWh** für das HA Energie-Dashboard.
### Netzenergie Import / Export (für Energie-Dashboard)
| Name | Adresse | Typ | Multiplikator | Einheit |
|------|---------|-----|---------------|---------|
| Energy Import Total | 1046 | U_DWORD | 0.1 | kWh |
| Energy Export Total | 1050 | U_DWORD | 0.1 | kWh |
---
## Hinweise
- **U_DWORD** = 32-Bit-Wert über 2 aufeinanderfolgende Register. ESPHome liest diese automatisch korrekt, wenn `value_type: U_DWORD` gesetzt ist.
- Passwörter und API-Keys sind durch `#` ersetzt und müssen vor dem Einsatz angepasst werden.
- Diese Config wurde für den SPH 5000 TL3-BH-UP verifiziert. Andere SPH-Modelle (SPH 3000, SPH 6000 usw.) verwenden dieselbe Registerstruktur.