esphome:
|
||||
name: growatt-mod-6000
|
||||
friendly_name: Growatt MOD 6000 TL3-XH
|
||||
|
||||
esp8266:
|
||||
board: esp07s
|
||||
|
||||
logger:
|
||||
|
||||
api:
|
||||
encryption:
|
||||
key: "HIER_API_KEY_EINTRAGEN"
|
||||
|
||||
ota:
|
||||
- platform: esphome
|
||||
password: "HIER_OTA_PASSWORT_EINTRAGEN"
|
||||
|
||||
wifi:
|
||||
ssid: "HIER_WLAN_NAME_EINTRAGEN"
|
||||
password: "HIER_WLAN_PASSWORT_EINTRAGEN"
|
||||
ap:
|
||||
ssid: "Growatt MOD 6000 Fallback Hotspot"
|
||||
password: "HIER_HOTSPOT_PASSWORT_EINTRAGEN"
|
||||
|
||||
captive_portal:
|
||||
|
||||
time:
|
||||
- platform: homeassistant
|
||||
id: homeassistant_time
|
||||
|
||||
output:
|
||||
- id: light_bl
|
||||
platform: gpio
|
||||
pin: 16
|
||||
- id: light_gr
|
||||
platform: gpio
|
||||
pin: 0
|
||||
- id: light_rd
|
||||
platform: gpio
|
||||
pin: 2
|
||||
|
||||
uart:
|
||||
id: mod_bus
|
||||
tx_pin: 1
|
||||
rx_pin: 3
|
||||
baud_rate: 115200
|
||||
|
||||
modbus:
|
||||
id: modbus1
|
||||
uart_id: mod_bus
|
||||
|
||||
modbus_controller:
|
||||
- id: growatt
|
||||
address: 1
|
||||
modbus_id: modbus1
|
||||
setup_priority: -10
|
||||
on_online:
|
||||
then:
|
||||
- output.turn_on: light_gr
|
||||
on_offline:
|
||||
then:
|
||||
- output.turn_off: light_gr
|
||||
|
||||
script:
|
||||
- id: blink_blue
|
||||
mode: single
|
||||
then:
|
||||
- output.turn_on: light_bl
|
||||
- delay: 200ms
|
||||
- output.turn_off: light_bl
|
||||
|
||||
sensor:
|
||||
# --- PV Eingang ---
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV1 Voltage"
|
||||
address: 3003
|
||||
register_type: read
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
on_value:
|
||||
then:
|
||||
- script.execute: blink_blue
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV1 Current"
|
||||
address: 3004
|
||||
register_type: read
|
||||
unit_of_measurement: A
|
||||
device_class: current
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV1 Power"
|
||||
address: 3005
|
||||
register_type: read
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV2 Voltage"
|
||||
address: 3007
|
||||
register_type: read
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV2 Current"
|
||||
address: 3008
|
||||
register_type: read
|
||||
unit_of_measurement: A
|
||||
device_class: current
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "PV2 Power"
|
||||
address: 3009
|
||||
register_type: read
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
icon: mdi:solar-panel
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
# --- AC Ausgang / Netz (dreiphasig) ---
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "AC Output Power Total"
|
||||
address: 3023
|
||||
register_type: read
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Frequency"
|
||||
address: 3025
|
||||
register_type: read
|
||||
unit_of_measurement: Hz
|
||||
device_class: frequency
|
||||
state_class: measurement
|
||||
icon: mdi:sine-wave
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 2
|
||||
filters:
|
||||
- multiply: 0.01
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Voltage L1"
|
||||
address: 3026
|
||||
register_type: read
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Current L1"
|
||||
address: 3027
|
||||
register_type: read
|
||||
unit_of_measurement: A
|
||||
device_class: current
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Voltage L2"
|
||||
address: 3030
|
||||
register_type: read
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Current L2"
|
||||
address: 3031
|
||||
register_type: read
|
||||
unit_of_measurement: A
|
||||
device_class: current
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Voltage L3"
|
||||
address: 3034
|
||||
register_type: read
|
||||
unit_of_measurement: V
|
||||
device_class: voltage
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Grid Current L3"
|
||||
address: 3035
|
||||
register_type: read
|
||||
unit_of_measurement: A
|
||||
device_class: current
|
||||
state_class: measurement
|
||||
icon: mdi:flash
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
# --- Energie (PV Erzeugung) ---
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Energy Today"
|
||||
address: 3049
|
||||
register_type: read
|
||||
unit_of_measurement: kWh
|
||||
device_class: energy
|
||||
state_class: total_increasing
|
||||
icon: mdi:solar-power
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Energy Total"
|
||||
address: 3051
|
||||
register_type: read
|
||||
unit_of_measurement: kWh
|
||||
device_class: energy
|
||||
state_class: total_increasing
|
||||
icon: mdi:solar-power
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
# --- Temperatur ---
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Inverter Temperature"
|
||||
address: 3093
|
||||
register_type: read
|
||||
unit_of_measurement: "°C"
|
||||
device_class: temperature
|
||||
state_class: measurement
|
||||
icon: mdi:thermometer
|
||||
value_type: U_WORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
# --- Smartmeter (optional, nur wenn Smartmeter angeschlossen) ---
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Power To User"
|
||||
address: 3041
|
||||
register_type: read
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
icon: mdi:transmission-tower-import
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
|
||||
- platform: modbus_controller
|
||||
name: "Power To Grid"
|
||||
address: 3043
|
||||
register_type: read
|
||||
unit_of_measurement: W
|
||||
device_class: power
|
||||
state_class: measurement
|
||||
icon: mdi:transmission-tower-export
|
||||
value_type: U_DWORD
|
||||
accuracy_decimals: 1
|
||||
filters:
|
||||
- multiply: 0.1
|
||||
@@ -0,0 +1,67 @@
|
||||
# Growatt MOD 6000 TL3-XH — ESPHome Konfiguration
|
||||
|
||||
Modbus-RTU Integration des Growatt MOD 6000 TL3-XH (dreiphasiger String-Wechselrichter, kein Hybrid) über einen Growatt SuniStick mit ESPHome-Firmware.
|
||||
|
||||
---
|
||||
|
||||
## Modbus-Register Übersicht
|
||||
|
||||
Alle Register sind **Input Register** (Modbus Funktionscode 04, `register_type: "read"`).
|
||||
Modbus-Adresse des Geräts: `0x01`
|
||||
|
||||
> **Wichtig:** Die MOD TL3-XH Serie verwendet 3000er-Register — nicht die kleinen Register der MIC/MIN-Serie.
|
||||
|
||||
### PV Eingang
|
||||
|
||||
| Name | Adresse | Typ | Multiplikator | Einheit |
|
||||
|------|---------|-----|---------------|---------|
|
||||
| PV1 Voltage | 3003 | U_WORD | 0.1 | V |
|
||||
| PV1 Current | 3004 | U_WORD | 0.1 | A |
|
||||
| PV1 Power | 3005 | U_DWORD | 0.1 | W |
|
||||
| PV2 Voltage | 3007 | U_WORD | 0.1 | V |
|
||||
| PV2 Current | 3008 | U_WORD | 0.1 | A |
|
||||
| PV2 Power | 3009 | U_DWORD | 0.1 | W |
|
||||
|
||||
### AC Ausgang / Netz (dreiphasig)
|
||||
|
||||
| Name | Adresse | Typ | Multiplikator | Einheit |
|
||||
|------|---------|-----|---------------|---------|
|
||||
| AC Output Power Total | 3023 | U_DWORD | 0.1 | W |
|
||||
| Grid Frequency | 3025 | U_WORD | **0.01** | Hz |
|
||||
| Grid Voltage L1 | 3026 | U_WORD | 0.1 | V |
|
||||
| Grid Current L1 | 3027 | U_WORD | 0.1 | A |
|
||||
| Grid Voltage L2 | 3030 | U_WORD | 0.1 | V |
|
||||
| Grid Current L2 | 3031 | U_WORD | 0.1 | A |
|
||||
| Grid Voltage L3 | 3034 | U_WORD | 0.1 | V |
|
||||
| Grid Current L3 | 3035 | U_WORD | 0.1 | A |
|
||||
|
||||
### Energie (PV Erzeugung)
|
||||
|
||||
| Name | Adresse | Typ | Multiplikator | Einheit |
|
||||
|------|---------|-----|---------------|---------|
|
||||
| Energy Today | 3049 | U_DWORD | 0.1 | kWh |
|
||||
| Energy Total | 3051 | U_DWORD | 0.1 | kWh |
|
||||
|
||||
### Temperatur
|
||||
|
||||
| Name | Adresse | Typ | Multiplikator | Einheit |
|
||||
|------|---------|-----|---------------|---------|
|
||||
| Inverter Temperature | 3093 | U_WORD | 0.1 | °C |
|
||||
|
||||
### Smartmeter (optional)
|
||||
|
||||
Nur relevant wenn ein Smartmeter am Wechselrichter angeschlossen ist.
|
||||
|
||||
| Name | Adresse | Typ | Multiplikator | Einheit |
|
||||
|------|---------|-----|---------------|---------|
|
||||
| Power To User (Bezug) | 3041 | U_DWORD | 0.1 | W |
|
||||
| Power To Grid (Einspeisung) | 3043 | U_DWORD | 0.1 | W |
|
||||
|
||||
---
|
||||
|
||||
## Hinweise
|
||||
|
||||
- **Dreiphasig, kein Hybrid, kein Batterie-Interface.**
|
||||
- Registerstruktur verifiziert gegen Growatt MOD TL3-XH Modbus-Protokoll (gleiche Familie wie MOD 7000 TL3-XH).
|
||||
- Ohne angeschlossenen Smartmeter liefern Register 3041/3043 Nullwerte — diese Sensoren können dann entfernt werden.
|
||||
- Passwörter und API-Keys sind durch Platzhalter ersetzt und müssen vor dem Einsatz angepasst werden.
|
||||